97色干-无码人妻精品一区二区-房奴试爱42分钟的床戏-男女拍拍视频-黑人操亚洲女人-仙踪林av-看片黄全部免费-亚洲精品国产一区-亚洲一区日韩-夫妻黄色片-久久资源365-色av网站-黄色性生活一级片-黄免费观看-综合久久久久久久-亚洲成人黄色网址-变态另类一区-国产情侣av在线-亚洲乱码国产乱码精品精大量-日韩午夜网站-国产精品怡红院-波多野结衣a级片-成人午夜看片-岛国在线免费观看-久久久精品人妻一区二区三区四-蜜臀av一二三区-免费欧美一级视频-久久伦理网站

Location: Home >>News >>Company News

Transmission Line Fault Monitoring System, Focusing on Distributed Fault Diagnosis and Location Warning

Author: Click:211 Time:2025-04-11

In the modern energy supply system, overhead transmission lines span mountains and rivers, traverse villages and towns, and shoulder the important res

In the modern energy supply system, overhead transmission lines span mountains and rivers, traverse villages and towns, and shoulder the important responsibility of sending electricity from power plants to thousands of households and industrial enterprises. However, due to long-term exposure to the open air environment, transmission lines continue to suffer from nature's assault, the sun, wind and rain, low temperature ice and snow, as well as the complexity of the changing geographic environment, which also led to all kinds of faults occur from time to time.




 As the transmission line distance is long, across different management units, based on this, I have prepared this very practical overhead transmission line fault diagnosis and location guide.

 developed and produced Transmission Line Faults.Transmission Line Fault Monitoring System (Distributed Fault Diagnosis Device)DX-WPS100-GZ01 is generally applicable to the analysis and positioning of tripping faults, lightning strikes and other faults on power lines of 35kV and above voltage levels, specifically through the unfolding of the transmission line disturbance sensing, to realize the abnormal diagnosis of the transmission line, analyze and locate the fault location points with high precision.

Working Principle

Contact distributed fault diagnostic device is distributed and installed on one side of transmission conductor, collecting traveling wave current signal and industrial frequency signal at the moment of fault at high speed, with the continuous recording of traveling wave current ≥1000μs, and sending the data back to the backstage data center through the communication module to carry out the automatic positioning of the fault location, analyzing the cause of the fault, and sending the diagnostic results to the operation and maintenance personnel in the form of WEB, SMS and so on.

Installation Cases

Our Distributed Fault Diagnostic Device is fully qualified, functionally stable, and meets the technical requirements of the State Grid South Network.

Distributed Fault Diagnostic Device is fully qualified, functionally stable, and meets the technical requirements of the State Grid South China Network. In addition to contact distributed fault diagnosis, we also provide non-contact fault diagnostic device, high-voltage cable fault and hidden danger monitoring system, distribution network traveling wave fault location device and a series of transmission and distribution substation online monitoring and fault location solutions and equipment.



Related recommendations

The online monitoring, distributed fault location and cable online monitoring equipment for power transmission and distribution lines launched by DINSEE SMART TECHNOLOGY CO.,LTD. has been widely used in Southern Power Grid and State Grid, and has achieved good results.

Record No.: Yue ICP Bei 2022070794-1 | Website Map XML Map